CVU-**-EFP1-3* Series
Basic Characteristics
Nominal sizes [ISO 7368 (DIN 24342)]:
06 (NG16)
08 (NG25)
09 (NG32)
10 (NG40)
Max. operating pressure: 315 bar (4500 psi)
Flow ratings: up to 900 L/min (238 USgpm)
Amplifier
Danfoss-Vickers model EEA-PAM-571-A, to be ordered separately. Power input 20-34V DC, 24V DC nominal.
General Description
Proportional throttle (restrictor) valves for use where one or more of the following requirements exist.
- Remote control of machine actuator speed, linear or rotary.
- Speed control in accordance with machine operating cycles or programs.
- Meter-in, meter-out or bleed-off application of the throttle valve itself.
- Pressure compensated flow control with the aid of a pressure hydrostat module, in any of the same three application modes.
- Smooth control of machine acceleration and/or deceleration.
- For industrial and mobile applications.
Features and Benefits
- New 09 (NG32) size.
- Valves suitable for unidirectional and bidirectional control of flow.
- 4 valve sizes offer choice of flow capacities
06 (NG16): 190 L/min (50 USgpm) at 10 bar (145 psi) Δp.
08 (NG25): 450 L/min (119 USgpm) at 10 bar (145 psi) Δp.
09 (NG32): 700 L/min (185 USgpm) at 10 bar (145 psi) Δp.
10 (NG40): 900 L/min (238 USgpm) at 10 bar (145 psi) Δp. - Designed for zero leakage when closed.
- Common amplifier for any valve size minimizes inventory.
- 24V DC nominal supply to amplifier to suit state-of-art control systems.
- Choice of command signals.
- Acceleration and deceleration requirements can be adjusted on-site by “ramp” potentiometer.
- Facility for on-site adjustment of “deadband” compensation and “gain”.
- Setting-up and fault diagnosis eased by panel display and signal monitoring points.
Functional Symbol
CVU-**-EFP1
Wiring Connections