This reversing valve is designed for use in hydraulic Dualine systems. It can be used as a 4/2 or a 3/2 valve and is driven by a direct current geared motor. When using SA-H as 2/2-way valve with port A, 1 port B has to lead back into the reservoir and close the opposite one.
Features
Technical Data
Working pressure max | 400 bar |
Temperature range | -20°C up to +80°C |
Action time | approx. 0.5s |
Angle of rotation | 180° |
Tightening torque | 18 Nm |
Torque | 4 Nm |
Operating voltage | 110 to 127 and 200 to 240 VAC; 24 VDC |
Cable gland | M25 x 1.5 |
Power consumption max | 42 W |
Protection system | IP 65 |
Installation position | optional |
Weight | 13 kg |
Operation by means of a geared D.C. motor with high torque ensuring reliable action even under unfavorable operating conditions (e.g. low temperatures or tough lubricant).
Because of the short action times, the plunger passes through critical valve settings with little overlap, at high speed, thereby avoising premature wear.
Each of the plunger end positions is electrically monitoring by a limit switch.
The motor’s overrun and direction of rotation have no effect on the limit switch setting ot the precision of the change-over.
A transformer, rectifier and automatic cut-out are incorporated, for connection to a AC 110-127V or 200-240V supply.
How To Order
When ordering specify by name, description and part number, e.g. SA-V Reversing, 110-127 VAC and 200-240 VAC, Part # SAV11A00
Name | Description | Part # |
SA-H | 110-127 VAC and 200-240 VAC | SAH11A00 |
24 VDC | SAH24A00 |