DC42 stations have been designed to meet the rigorous requirements of heavy industry. They can supply either oil or grease to such installations as bar mills, billet mills, blast furnaces and sintering machines. On DC42 stations, pressure is controlled by the reversing valve (DR45). The valve opens a micro switch, which stops the pump motor when system pressure rises to its setting. Timer controls for each type tailored to meet its specific requirements are available.
Technical Data
Pump Output | 33.6 in3/min |
Pump Type | Double Piston |
Max. Work Pressure | 3000 psi |
Relief Pressure | 2500 psi |
Gear Ratio-Std. | 10:1 |
Pump # | DJ-2000 |
Reversing Valve | DR4-5 |
Rev. Press-Factory Setting | 1500 psi |
Rev. Press-Range | 500-3500 psi |
Motor | Optional |
Motor HP | 1 |
Motor Enclosure | TEFC |
Motor Frame Size | 143/145T |
Low Level Switch | Optional |
High Level Switch | Optional |
Rev. Valve Limit Switch | Yes |
Lubricant | Oil/Grease |
System Type | Non-Return 1 |
1 Field Conversion for Loop Operation
How to order
Model | Voltage | Reservoir | Level Switches | Part Number | ||
Low | High | With Motor | W/O Motor | |||
DC42 | Three Phase 230/460 VAC (50/60 Hz) | 30 gallon steel | x | x | DC42M33D | DC4233D |
100 lb steel | x | x | DC42M31C | --- | ||
200 lb steel | x | x | DC42M32C | DC4232C |