DC41 stations have been designed to meet the rigorous requirements of heavy industry. They can supply either oil or grease to such installations as bar mills, billet mills, blast furnaces and sintering machines. On DC41 stations, pressure is controlled by a pressure switch (one is installed in each line) that actuates the reversing valve (FR10) and stops the pump motor when system pressure rises to its setting.
Technical Data
Pump Output | 33.6 in3/min |
Pump Type | Double Piston |
Max. Work Pressure | 3000 psi |
Relief Pressure | 2500 psi |
Gear Ratio-Std. | 10:1 |
Pump # | DJ-2000 |
Reversing Valve | FR20 (SOL type) |
Rev. Press-Factory Setting | N.A. 2 |
Rev. Press-Range | N.A. 2 |
Motor | Optional |
Motor HP | 1 |
Motor Enclosure | TEFC |
Motor Frame Size | 143/145T |
Low Level Switch | Optional |
High Level Switch | Optional |
Rev. Valve Limit Switch | No |
Lubricant | Oil/Grease |
System Type | EOL |
2 Controlled by end of line pressure switches (see Catalog #1800G: Fittings, Accessories, Regulators and Lubricators)
How to order
Model | Voltage | Reservoir | Level Switches | Part Number | ||
Low | High | With Motor | W/O Motor | |||
DC41 | Three Phase 230/460 VAC (50/60 Hz) | 100 lb steel | x | x | DC41M31C | --- |
200 lb steel | DC4132A | |||||
x | x | DC41M32C | DC4132C |