DC36 stations store, control, and supply lubricant to systems. The lubricant must be oil with a viscosity of not greater than 1900 SSU at 100°F. DC36 stations can be used in systems that service equipment requiring oil lubrication such as machine tools and transfer equipment.
Standard items on these stations include a low level warning switch for connection to lights or horns, oil level sight gauge, a 30 mesh oil filter and an air breather cap in the oil filler port.
Technical Data
Pump | Gear type with discharge capacity of 0.30 GPM at 0 psi and at 1725 RPM. Relief valve is normally set at 1000 psi. |
Electric Motor | Standard motor is 1/3 HP at 1750 RPM, 120 volts-60 cycles. Motors with other HP ratings and for other voltages are available. |
Reservoir | Available in three sizes - 15, 30, and 50 gallons. All have an oil sight gauge, a 30 mesh oil filter (100 mesh screen available upon request), an air breather cap in the oil filler port, and a low oil-level warning switch for connecting to warning lights or horns. A high level warning switch is optional. |
Lube Timing Device (Optional) | Model K5 timer starts and monitors each lube cycle. It operates warning lights or horns if system fails to reverse. Standard timer is for 120 volts-60 cycles with either a one or twenty-four hour dial. Timers for other voltages (consult factory) |
Pressure Control Device | This is a DR2-7 type reversing valve with limit switch. |
HOW TO ORDER
Model | Voltage | Reservoir | With Motor |
DC36-7BP | 120 VAC (50/60 Hz) | 15 Gallon | No |
201096 | Yes | ||
DC36-8BP | 30 Gallon | No | |
201097 | Yes | ||
DC36-9BP | 50 Gallon | No | |
201098 | Yes |