The ENS 3000 is an electronic level switch with integrated display. The instrument has 1, 2 or 4 switching outputs and an analog output signal is available as an option.
In addition to the standard minimum and maximum switching signals, with the 4 switching output version it is possible to set additional warning signals to prevent problems such as tank overflow or aeration of the pump. The ENS 3000 can be used for oil as well as water. The fluid type can be selected for specific applications via the menu.
The main applications of the ENS 3000 are primarily in hydraulics, e.g. for fluid level monitoring of a tank.
The ENS 3000 is available in standard probe lengths of 9.80", 16.20", 20.50" and 28.70".
The instrument is also available with or without an integrated temperature sensor.
Special features:
Setting options:
All settings available on the ENS 3000 are combined in 2 easy-to-navigate menus. To prevent unauthorized adjustment of the instrument, a programming lock can be set.
Setting ranges of the switching points and switch-back hysteresis:
Fluid level switching point function
Probe length in inches | Meas. range in inches | Switching point in inches | Hysteresis in inches |
9.80 | 6.70 | 0.10 .. 6.70 | 0.05 .. 6.60 |
16.20 | 11.40 | 0.20 .. 11.40 | 0.05 .. 11.25 |
20.50 | 15.35 | 0.25 .. 15.35 | 0.05 .. 15.15 |
28.7 | 23.20 | 0.35 .. 23.20 | 0.15 .. 22.85 |
The increment for all units is 0.05 inch.
Fluid level window function
Probe length in inches | Lower switch value in inches | Upper switch value in inches |
9.80 | 0.10 .. 6.55 | 0.20 .. 6.60 |
16.20 | 0.20 .. 11.15 | 0.30 .. 11.25 |
20.50 | 0.25 .. 15.05 | 0.35 .. 15.15 |
28.7 | 0.40 .. 22.80 | 0.60 .. 22.85 |
The increment for all units is 0.05 inch.
Fluid level offset function
Probe length in inches | Meas. range in inches | Offset in inches |
9.80 | 6.70 | 0 .. 26.8 |
16.20 | 11.40 | 0 .. 45.6 |
20.50 | 15.35 | 0 .. 61.4 |
28.7 | 23.20 | 0 .. 69.6 |
The increment for all units is 0.05 inch.
Temperature switching point function
Meas. range | Switching point | Hysteresis |
-13 .. +212 °F | -9 .. +212 °F | 2 .. 222 °F |
The increment for all units is 1 °F.
Temperature window function
Lower switch value | Upper switch value |
-10 .. +212 °F | -10 .. +212 °F |
The increment for all units is 1 °F.
All ranges given in the table are adjustable by the increments shown.
Additional functions: