Mounting Method | 4 Mounting holes - filter housing |
Port Connection | 30 | ½” Threaded / 0.71” Dia Smooth | 60/110 | SAE-12 / SAE-12; 3/4” NPT / SAE-12 | 160/240 | SAE-20 / SAE-20; 1 1/4” NPT (with adapter) / SAE-20 SAE-20 / 2” NPT (with flange port adapter) | 330 | 2” Threaded (NPT/BSPP/SAE) / same as inlet 2” SAE Flange, Code 61 / 2” NPT | 660 | 3” SAE Flange, Code 61 / 3” NPT 3” SAE Flange, Code 61 / 3” SAE Flange, Code 61 | 950 | 3-1/2” SAE Flange, Code 61 / 3-1/2” SAE Flange, Code 61 | 1300 | 4” SAE Flange, Code 61 / 4” SAE Flange, Code 61 |
|
Flow Direction | Inlet: Side Outlet: Bottom |
Construction Materials | 30 60-330 660-1300 | Housing Polyamide Aluminum Ductile Iron | Lid Polyamide Aluminum Ductile Iron |
|
Flow Capacity | 30 60 110 160 240 330 660 950 1300 | 8 gpm (30 lpm) 16 gpm (60 lpm) 29 gpm (110 lpm) 42 gpm (160 lpm) 63 gpm (240 lpm) 87 gpm (330 lpm) 174 gpm (660 lpm) 251 gpm (950 lpm) 343 gpm (1300 lpm) |
|
Housing Pressure Rating | Max. Allowable Working Pressure 360 psi (25 bar); (size 30 - 145 psi, 10 bar) Fatigue Pressure 1478 psi (33 bar) @ 700,000 cycles; Burst Pressure | 30 60/110 160/240 330 660-1300 | 580 psi (40 bar) 1080 psi (75 bar) 1230 psi (85 bar) 1440 psi (100 bar) 3045 psi (210 bar) |
|
Element Collapse Pressure Rating | BH4HC, V 3045 psid (210 bar) ON, W/HC 290 psid (20 bar) V 435 psid (30 bar) |
Fluid Temp. Range | 14°F to 212°F (-10°C to 100°C) |
Fluid Compatibility | Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected. |
Indicator Trip Pressure | ∆P = 29 psid (2 bar) -10% (optional) ∆P = 72 psid (5 bar) -10% (standard) |
Bypass Valve Cracking Pressure | ∆P = 43 psid (3 bar) +10% (optional) ∆P = 87 psid (6 bar) +10% (standard sizes 160 - 660) |