The HY-TTC 94 is an extremely robust and powerful electronic control unit for use in off-highway applications. This controller compliance with the international EN ISO 13849 standard and has been certified by TÜV Nord; It meets the requirements of Functional Safety according to Performance Level (PL) d.
The HY-TTC 94 is equipped with the Infineon XC2287M CPU providing enhanced safety features for protecting internal RAM and flash. This variant is part of a complete and compatible product family and is protected by a compact, automotive-style housing suited to mobile applications in harsh environments.
Features
All I/Os and interfaces mentioned below are protected against short circuit to GND and BAT+.
CPU Core
Interfaces
Outputs
Inputs
Other
Software
Specifications
Parameter | |
ECU Dimensions | 147.6 x 180.3 x 39.8 mm |
Dimensions for Minimum Connector Release Clearance | 197.7 x 202.8 x 39.8 mm |
Weight | 650 g |
Operating Temperature | - 40 to +85 °C (full load) - 40 to +105 °C (lim. load) |
Operating Altitude | 0 to 4000 m |
Supply Voltage | 8 to 32 V |
Peak Supply Voltage | 45 Vmax |
Max Idle Current | 0.15 Amax at 9V |
Standby Current | 0.5 mA |
Total Load Current | 25 Amax |
Standards | |
Functional Safety | Designed for ISO 13849 PL b |
CE-Mark | 2014/30/EU 2006/42/EC |
E- Mark | ECE-R10 Rev.4 |
EMC | SO 13766, up to 200 V/m, 20 MHz to 1GHz |
ESD | IEC61000-4-2 |
Load Dump | ISO7637-2, 173 V, 2 Ohm |
Ingress Protection | EN 60529 IP67 ISO 20653 IP6k9k |
Temperature | EN 60068-2-1, -14Nb, -2, -78, -30 |
Vibration, Shock, Bump | IEC 60068-2-29, -64, -27, -32 |
Housing and Connector