CVI (Check, Directional and Flow Restrictor)

CVI inserts

eaton cvi inserts

Eaton-Vickers type “CVCS” cartridge covers conform to installation requirements of ISO 7368 and DIN 24342. This includes port usage changes to the D3, PC, W and Metric Models Metric bolt tappings and orifice threads; SAE plugs.

Check Valve Functions

Basic Check Valve: Sizes 16 to 63

The standard directional cover (model code letter N), contains a pilot pressure passage with an orifice to control the poppet’s opening and closing rate. When used with insert model D15 (1:1.5 area ratio poppet), or model D20 (1:2 area ratio poppet), the combined cover and insert, becomes a check valve. Port X in the cover is connected to port B in the insert. This allows free flow from insert port A to port B while blocking flow from B to A.

Direct Acting Check: Sizes 16 to 63

The type DC15 insert is used with the type B cover to provide a direct check function. The free flow direction is A to B. Flow in the opposite direction (B to A) is prevented by connecting port B to the full poppet area AAP, via drilled holes on the poppet, whereby any pressure at port B assists the spring in holding the poppet hard on to its seat.

Pilot Operated Check Valve (Pilot Open): Sizes 16 to 63

A model PC cover can be combined with a model D15 insert to form a pilot operated check valve. Pilot pressure at Z1 vents spring chamber AP to Y, permitting flow from B to A. Flow from A to B is independent of pilot pressure. With port B connected to the system load, pilot pressure at Z1 must be at least 30% of load pressure, the latter including any intensification that may occur such as when controlling double-acting cylinders. Port Y is normally connected to a drain line.

Directional Valve Functions

2-Way, 2-Position Function: Sizes 16 to 63

Using a model N cover with a D15 insert, can provide directional control of flow from insert port A to B or from B to A. Pressurizing port X from a remote source will block flow from insert port A and B. With X connected to B, system flow is from A to B. Flow will be from B to A if X is connected to tank or A.

2-Way, 2-Position Function (With Internal Pilot): Sizes 16 to 63

A model N cover is used with a D105 insert (1:1.05 area ratio) which can be supplied with an orifice in the poppet. This configuration is used to open A to B or block A to B. D105 poppets cannot be used for flow from B to A. The orifice avoids the need to machine a connecting hole in the manifold to port A. To obtain a D105 insert with an orifice in the poppet (i.e. D105V), the orifice size must be specified at the end of the insert model number.

Damping Function: Sizes 16 to 63

Damping can be achieved with a model R15 insert (area ratio 1:1.5) and R20 (area ratio 1:2). The poppet has a skirt with a damping notch which helps smooth shifting (reduces gain) of the poppet. R15/R20 inserts may be used with any check or directional function where a D15/D20 insert is ordinarily used.

Pilot Operated Directional Valves: Sizes 16 to 63

Covers are available with mounting interfaces for pilot valves. These pilots are typically the DG4V-3(S) solenoid operated directional valve that mounts to the ISO 4401, size 03 (ANSI/ B93.7M-D03) interface. Manually operated DG17V-3, pilot operated DG3V-3, or air operated DG18V-3 pilots are also applicable. The Eaton-Vickers soft shift pilot valves DG4V-3- ****2** can also be used to achieve smooth opening and closing.

Single or dual solenoid pilots are applicable, depending on circuit requirements. The spool center condition of the solenoid pilots also depends on the circuit function desired. Ports Z1 and Z2 are for remote control of additional cartridges. That is, for D3 covers, Z1 is connected to pilot port A. The X port is the pilot pressure port. The Y port should always go directly to the reservoir. The insert used can be either the model D15 (1:1.5 area ratio poppet), or model D20 (1:2 area ratio poppet).

Pilot Operated Directional Valves with Shuttle Function

The shuttle function in combination with a solenoid operated pilot valve is available in cartridge sizes 16 through 63. In each cartridge size, the pilot valve is the DG4V-3 that mounts to the ISO 4401, size 03 (ANSI/B93.7M-D03) interface. There are two functional cover types, W13 and W33, that are applied with a model DG4V-3 pilot valve. The insert used can be either the model D15 (1:1.5 area ratio poppet), or model D20 (1:2 area ratio poppet).

Shuttle Type 1 (W13 Cover): Sizes 16 to 63

With the solenoid de-energized, Figure 17, the cartridge is shut by the higher of the pressures at X or Z1 . Pilot port Z2 can be used to pilot a second cartridge simultaneously.

Shuttle Type 3 (W33 Cover): Sizes 16 to 63

The function of the W33 cover, Figure 18, is to provide a nonreverse-flow check, thereby eliminating the need for a separate back flow check. Flow is either blocked or allowed from port B to port A. Flow from port A to port B is always blocked. The application would have pump flow going into port B, port A connected to the actuator and control port X connected to port A.

Dual Check (DC3 Cover): Sizes 16 to 63

The DC3 cover, Figure 19, provides parallel check functions in pilot control ports X and Z1. The higher of these two pressures is then available at pilot port P to close the insert via the size 03 solenoid operated valve. A second cartridge can be operated simultaneously from pilot port Z2. The DC3 cover is similar to the type W13 cover but, whereas there is an open transient condition in the shuttle function (type W13), the DC3 design uses two check valves to ensure that no transient loss of pressure in port P can occur during pilot pressure change-over between ports X and Z1. This feature is of benefit in any application where there must be absolutely no risk of the cartridge even momentarily opening during pilot pressure changeover.

Stroke Limiter Control Functions

Flow control is by means of a standard cover with a stroke adjuster which limits the stroke of any of the inserts and thereby limits the flow.

Size 16 to 63

The R10 insert (1:1), R15 insert (1:1.5), R20 insert (1:2) has smaller skirt and used as dampening function as well as for fine flow metering (reduced flow gain) during the notch engangement. The F15 insert (1:1.5) & F20 insert (1:2) are the flow control functions with longer skirt and longer notch, hence more notch engagement enabling flow metering over larger stroke.

Adjustable Stroke Limiter and Directional Functions: Sizes 16 to 63

The adjustable limiting of the insert poppet opening restricts flow in both directions (A to B and B to A). Control is from pilot port X

Adjustable Stroke Limiter and Pilot (Directional) Function: Sizes 16 to 63

Stroke limiters are available with an ISO 4401, size 03 (ANSI/ B93.7M-D03) interface for mounting a single-solenoid controlled DG4V-3(S) pilot valve. These type A3 covers are supplied configured for a “normally open” function, i.e. the insert poppet is vented when the solenoid of the pilot valve is de-energized (with pilot pressure applied to port X).

The opposite, “normally closed” (NC) function, can be obtained by interchanging the orifice and plug in ports AP1/AP2. With this arrangement, the insert poppet is “normally closed” (NC) and is open when the solenoid of the pilot valve is energized (with pilot pressure applied to port X)

Adjustable Stroke Limiter and Check Functions: Sizes 16 to 63

The adjustable poppet lift limiter restricts flow from A to B. The check function prevents flow from B to A. The X pilot port of the cover is connected to the B port of the insert

Sort by
Display per page

CVI-16-D105-H-50

P/N# 847AN00087A Eaton Vickers Slip-in Cartridge Valve Insert
Call for pricing

CVI-16-D105-L-50

P/N# 847AN00049A Eaton Vickers Slip-in Cartridge Valve Insert
Call for pricing

CVI-16-D105-M-50

P/N# 847AN00058A Eaton Vickers Slip-in Cartridge Valve Insert
Call for pricing

CVI-16-D105V-H-50

P/N# 847AN00144A Eaton Vickers Slip-in Cartridge Valve Insert
Call for pricing

CVI-16-D105V-L-50

P/N# 847AN00106A Eaton Vickers Slip-in Cartridge Valve Insert
Call for pricing

CVI-16-D105V-M-50

P/N# 847AN00140A Eaton Vickers Slip-in Cartridge Valve Insert
Call for pricing

CVI-16-D15-H-50

P/N# 847AN00075A Eaton Vickers Slip-in Cartridge Valve Insert
Call for pricing

CVI-16-D15-L-50

P/N# 847AN00078A Eaton Vickers Slip-in Cartridge Valve Insert
Call for pricing

CVI-16-D15-M-50

P/N# 847AN00010A Eaton Vickers Slip-in Cartridge Valve Insert
Call for pricing

CVI-16-D20-H-50

P/N# 847AN00045A Eaton Vickers Slip-in Cartridge Valve Insert
Call for pricing

CVI-16-D20-L-50

P/N# 847AN00027A Eaton Vickers Slip-in Cartridge Valve Insert
Call for pricing

CVI-16-D20-L-50-EN106

P/N# 02-414480 Eaton Vickers Slip-in Cartridge Valve Insert
Call for pricing