Cartridge Valve Insert

Function D105V - 1:1.05 ratio with variable orifice plug

A model N cover is used with a D105V insert (1:1.05 area ratio) which can be supplied with an orifice in the poppet. This configuration is used to open A to B or block A to B. D105V poppets cannot be used for flow from B to A. The orifice avoids the need to machine a connecting hole in the manifold to port A. To obtain a D105V insert with an orifice in the poppet, the orifice size must be specified at the end of the insert model number.

Picture for CVCS-W33 data-lazyloadsrc=