Cartridge Valve Cover

Function U3 - Unloading relief with mounting face for size 03 pilot valve

Pilot connection A to Z1 is needed to ensure the pressure relief function A to B. Pump flow at port A can be unloaded by application of pilot pressure to port X. This pressure must be equal to the pressure setting of the unloader pilot stage to initiate unloading; the system pressurizes again when this pressure drops by approx. 20% or more.

Picture for CVCS-U3