Cartridge Valve Cover

Function Type A3 - Stroke adjuster with mounting face for size 03 pilot valve

Stroke limiters are available with an ISO 4401, size 03 (ANSI/ B93.7M-D03) interface for mounting a single-solenoid controlled DG4V-3(S) pilot valve. These type A3 covers are supplied configured for a “normally open” function, i.e. the insert poppet is vented when the solenoid of the pilot valve is de-energized (with pilot pressure applied to port X).

The opposite, “normally closed” (NC) function, can be obtained by interchanging the orifice and plug in ports AP1/AP2. With this arrangement, the insert poppet is “normally closed” (NC) and is open when the solenoid of the pilot valve is energized (with pilot pressure applied to port X).

Picture for CVCS-A3